mini is more. puls gmbh, arabellastrasse 15, 81925 munich tel. +49.(0)89.9278-244, fax: +49.(0)89.9278-299 sales@puls-power.com, http://www.puls-power.com puls does it again: practical, versatile and reliable like the silverline ? yet small like no other. miniline ml100.102 mounted and connected within seconds, no tools required world-wide approvals (ul, en, csa, cb scheme) for industry and office/ home tiny: wxhxd = 73 x 75 x 103mm hazardous location class i div. 2 (ul 1604) adjustable output voltage up to dc 15v 115/230v auto select input selectable single/parallel operation (jumper) with dc 12-15v / 90w ml100e102/040629 data sheet
x input input voltage ac 100-120/220-240v (auto select), 47...63 hz (ac 85...132v / ac 184...264v, dc 220...375v, n= + and l= - ) input current <1.9a (@ ac 100v in , 90w p out ) <0.9a (@ ac 220v in , 90w p out ) external fusing not required, un it provides internal fuse (t3a15h, not accessible) transient immunity transient resi stance acc. to vde 0160 / w2 (750v/ 1.3 ms), over entire load range hold-up time (see diagram below) >40 ms @ ac 230v, 12v / 7.5a >20 ms @ ac 196v, 12v / 7.5a >20 ms @ ac 100v, 12v / 7.5a x efficiency, reliability efficiency losses >88.5% (ac 230v, 12v / 7.5a) (see also diagram below) <11.7w (ac 230v, 12v / 7.5a) mtbf (reliability) appr. 500.000 h acc. to siemensnorm sn 29500 (12v / 7.5a, ac 230v, t amb = +40 c) prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure: run-in / burn-in (full load, t amb = +60c, on/off cycle) functional test (100 %) x construction, mechanics, installation robust plastic housing (us patent no. d442, 923s), fine ventilation grid on three housing sides to keep out small parts (e.g. screws), ip20 dimensions and weight w x h x d weight 73 mm x 75 mm x 103 mm (+ din rail) depth incl. terminals: 98 mm (+ din rail) 360 g mounting orientation , or (cf. ?output?) ventilation/cooling free space f. cooling normal convection, no fan required recom'd.: 25 mm on sides with ventilation grid easy snap-on mounting onto the din-rail (ts35/7,5 or ts35/15). unit sits safely and firmly on the rail; no tools required even to remove connection by spring clamp terminals; uniformly firm hold, vibration-resistant and maintenance-free: 2 terminals per output connector size range flexible cable solid cable wire strip length 0.3-2.5mm 2 (28-12 awg) 0.3-4mm 2 (28-12 awg) ferrules admissible 6mm (0.24in) recommended x diagrams 0 2 4 6 8 10 12 14 16 012345678910 vin = ac 115/230 v single use vin = ac 115/230 v parallel use 0,0 20,0 40,0 60,0 80,0 100,0 120,0 140,0 160,0 180,0 80 100 120 140 160 180 200 220 240 260 280 pout = 90w,typ. pout = 90w, mi n. pout = 45w, typ. pout = 45w, mi n. 0 10 20 30 40 50 60 70 80 90 100 -10 0 10 20 30 40 50 60 70 75 77 79 81 83 85 87 89 91 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0 7,5 230vac 115vac output characteristic v out /i out (min.) efficiency hold-up time with acin (@ v out = 12v, typ.) (at v out = 12v, typ. + min.) derating of output power mounting 85-132 v acin a-a a-b a-b 184-264 v acin a-a a-b a-b 220-375 v dcin a-a a-b a-b a b a output current lout [a] output voltage vout [v] output current lout [a] efficiency [%] ambient temperature [c] output powwer [w] input voltage vacin[v] hold-up time [ms] x output output voltage preset dc 12-15v (adj. by front panel potentiometer) 12v 0.5% @ 7.5a voltage regulation stat. <1.5% v out (jumper in pos. 'single use') stat. <3% v out (jumper in pos. 'parallel use'), dyn. 2.5% v out over all ripple/noise <50mv pp (20 mhz bandw., 50 ? measurement) overvoltage prot. (ovp) <18.5v rated continuous loading up to 7.5a @ 12v/6a @ 15v (convection cooling), depending on built-in orientation, v in and t amb for details see derating diagram below overload behaviour straight v/i characteristic (depending on v in ); details see diagr. 'output characteristic' below protection unit is protected against (also permanent) short- circuit, overload and open-circuit. derating depending on built-in orientation; see diagram below parallel operation yes (selectable by front panel jumper) power back immunity 25v operating indicator green led x environmental data, emc, safety ambient temperature range (measured 25 mm below unit) storage/transport operation -25c ... +85c -10c ... +70c (for dera ting see diagram below) humidity max. 95% (without condensation) electromagnetic emissions (eme) en 61000-6-3 (includes en 61000-6-4) class b (en 55011, en 55022) en 61000-3-2 (pfc) electromagnetic immunity (emi) en 61000-6-2 (includes en 61000-6-1) safe low voltage: prot. class/degree: selv (en 60950, vde0100/t.410), pelv (en 50178) class 1 (en 60950) / ip20 (en 60529) the psu complies with all major safety approvals for eu (en 60 950, en 60204-1, en 50178), usa (ul 60950, e137006, ul508 listed, e198865), canada (can/csa-c22.2 no 60950 [cur], can/csa-c22.2 no. 14 [cul]), cb scheme (iec 60950). hazardous location class i div. 2 (ul 1604) design details ? for your advantage: all terminals are easy to reach as mounted on the front panel. input and output are strictly apart from each other (input below, out- put above) and so cannot be mixed up. ? mounting and connection do not require any screwdriver easy, quick, durable and reliable installation. technical data ml100 .102 product information (ml100e102), rev.: 29. june 2004. unless othe rwise stated, specifications ar e valid for ac 230v input volta ge, +25c ambient temperature, and 5 min. run-in time. they are subject to change without prior notice. puls gmbh, arabellastra?e 15, d-81925 mnchen x tel: +49.(0)89.9278-244, fax: +49.(0)89.9278-299, e-mail: sales@puls-power.com x www.puls-power.com s p r i n g c l a m p s
|